The main task of the Highway monitoring center is to ensure the normal operation of various subsystems and control equipment of the Highway, and to respond quickly in the event of an accident. Therefore, the Highway monitoring center is the nerve center of the entire Highway safety management and control system. With the detection equipment, the status of any equipment on the highway is quickly transmitted and collected in the monitoring center, so that managers can easily grasp all the conditions at any time.
The system collects the information of each smart device in the Highway power supply system, pushes an alarm signal through SMS or APP when there is an abnormality, and can dispatch work orders and perform tracking closed-loop processing.
The Difficulty of Highway Substation Operation and Maintenance
The Highlight of Highway Substation Operation and Maintenance Cloud Platform
The Solution for Highway Substation Operation and Maintenance
AcrelCloud-1000 Electric Power Operation and Maintenance Cloud Platform
Using multi-functional power sensors, wireless communication, edge computing gateways, and big data analysis technologies,
Collect on-site data through the intelligent gateway and store it locally, and then push the data to the cloud platform regularly.
The data collected by the platform includes the electrical parameters of the substation circuit and transformer temperature, ambient temperature and humidity, water immersion, smoke, video, access control, and other information.
If there is an abnormality, an alarm signal will be sent through SMS and APP within 10S.
The platform sends the operation and maintenance tasks to the designated personnel's mobile phones through the mobile APP.
And through GPS tracking the operation and maintenance execution process to close the loop,
Improve operation and maintenance efficiency, find and eliminate operational defects in real-time.
The Function of Highway Substation Operation and Maintenance Cloud Platform
The system adopts B/S architecture, and the system data and alarm information can be viewed through the computer WEB terminal, tablet, or mobile APP.
Overview, running status, event record of the day, hourly electricity consumption curve of the day, electricity consumption overview.
Support large-screen display of user operation and maintenance substation overview, environmental monitoring, real-time voltage, real-time load, real-time electricity, distribution diagram, etc.
Power data display the power data and curve of the substation circuit, the curve shows the large, small and average value in the statistical period, and supports exporting charts; it is convenient for users to query data through tables.
Display the harmonic data of the circuit of the substation and substation. You can select the harmonic data of a circuit by selecting the harmonic type and harmonic quantity.
The energy consumption report displays the energy consumption data of each circuit, including daily, monthly and annual reports, and the reports can be exported.
Leakage current and cable temperature and alarm conditions.
Equipment definition, equipment file, and equipment report, in the equipment file, the substation equipment is maintained and processed.
Task management, inspection records, and defect records have three parts,
Task management can complete task creation, release, and task completion queries;
The inspection record is the execution status and execution details of the inspection task;
The defect record is the query of the creation, release, and completion status of the defect elimination task.
The event record is convenient for operation and maintenance personnel to view and analyze the equipment.
Automatically summarize the operation data of a month for the selected substations, conduct statistical analysis on the transformer load, power consumption of the distribution circuit, power factor, alarm events, etc. Class defects and handling conditions.
The power operation and maintenance mobile phone support seven modules: "Monitoring System", "Equipment File", "To-Do List", "Inspection Record", "Defect Record", "Document Management" and "User Report". Volume, power consumption, video, curve, temperature and humidity, year-on-year, chain ratio, power quality, various event alarm queries, equipment file queries, to-do event processing, inspection record query, user report, document management, etc.
2014/35/EU
2014/30/EU
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
8 current input, 4 voltage input
16 DI, 10 DO
2 RS485, 1 RS232, 1 GPS
Powerful graphic programmable Logic
CE
RED
Radio Equipment Directive (RED) 2014/53/EU
2014/30/EU
EN IEC 61000
IEC 62052
IEC 62053
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]