Factory Energy Consumption Management System Solution

With carbon peaking and carbon neutrality becoming the main task of government work,

As a large-scale building with intensive energy consumption and a complex energy consumption situation, the factory

Effectively reduce energy consumption, reduce energy costs,

Avoid the phenomenon of "running and dripping" in the process of energy use,

The implementation of comprehensive energy efficiency evaluation is a very necessary management method.

Difficulty

What's the Difficulty of Factory Energy Consumption Management?

  • Data Delay
  • Local Control
  • Manual Statistics

Highlight

What's the Highlight of the Factory Energy Consumption Management System Solution?

  1. Real-time Monitoring
  2. Remote Control
  3. System Analysis

Configuration

How to Configure the Factory Energy Consumption Management System?

Establish an efficient energy consumption monitoring and management system to conduct real-time monitoring of energy usage and alarms at various points in the factory.

So that factory users can monitor the operation of each point in real-time, and at the same time, they can grasp the alarm of the point more quickly and efficiently, and provide data support for the factory's technical transformation measures such as peak shaving and valley filling, and load adjustment.

◆ Real-time monitoring of energy

Real-time monitoring of water, electricity, gas, and other energy consumption,

To ensure the safe, continuous, and stable operation of the energy-consuming link,

Display power distribution diagram, energy flow diagram, energy balance network diagram, energy metering network diagram, and other functions.

■ Energy flow diagram:

The consumption of water, electricity, and gas needs to be displayed in real-time on the energy flow diagram;

When the energy parameter exceeds the limit alarm, it can provide alarm importance classification, and support APP push alarm prompt, SMS alarm prompt, email, voice alarm prompt, etc.;

■ Distribution diagram:

Draw the real situation of the power distribution room in the power distribution diagram,

Real-time display of the real-time water and electrical parameters of the access control, water immersion, electricity, water, gas, and other instruments, and the access control water immersion status.

■ Real-time statistics:

Real-time statistics of energy consumption values ​​of factories, workshops, processes, and equipment in the current year, quarter, month, week, day, shift, etc.;

■ Data display:

Display different energy consumption parameters of different areas and different equipment through real-time curves and historical curves;

◆ Security Detection

Centralized display of energy alarm information,

processing alarm threshold information,

Set alarm parameters online,

Alarm importance level classification, with SMS, APP push, email, voice and other information alarm prompts

Function

What's the Function of Factory Energy Consumption Management System Solution?

Energy usage statistics

From the dimensions of energy use, workshop, production process, process, equipment, etc., use curves, pie charts, histograms, cumulative graphs, digital tables, etc. to make statistics on factory energy consumption, year-on-year, and ring-to-ring analysis, unit product energy consumption, unit Output value energy consumption statistics, to find loopholes and unreasonable places in the process of energy use, so as to adjust the energy distribution strategy and reduce waste in the process of energy use.

Transformer monitoring

Display the load conditions of each transformer, so as to make scientific and reasonable planning for the allocation of transformers. Through the comparative analysis of power efficiency under various operating parameters, find out the best operating mode and adjust the load, so as to reduce the unit power consumption and minimize the power loss.

Cost Analysis

Statistics of various energy consumption costs of each monitoring node (factory, workshop) for the year, quarter, month, week, and day.

Product unit consumption statistics

Docking with the factory MES system, through the product output and energy consumption data collected by the system, generate a product unit consumption trend chart in the product unit consumption, and conduct year-on-year and ring-to-ring analysis. At the same time, the unit consumption of the product is compared with the indicators of the industry/country/international advanced enterprises, so that the factory can adjust the production process according to the unit consumption of the product, thereby reducing energy consumption.

Performance Analysis

Perform daily, weekly, monthly, yearly, and designated period performance statistics on the use, consumption, and conversion of various types of energy by the team, area, workshop, production line, section, and equipment. Carry out KPI assessments in accordance with energy plans to help factories understand internal energy efficiency levels. and energy-saving potential to assess whether energy consumption is reasonable.

Carbon emission management

Statistics on the change trend of total carbon emissions by region, and a year-on-year analysis. Calculate the carbon emissions per unit of output value, and combine the emission reduction indicators to realize the early warning of exceeding the standard, improve the regional emission reduction level, and promote the realization of the carbon peak goal.

Customize energy consumption report

Users can view the energy consumption, unit consumption, cost, and other information of each node of the factory through custom reports, and support export.

Flow diagram of energy consumption

Visually display the current energy consumption flow through graphics, and the start date and end date can be selected.

Multiple rate report

Statistical analysis of peak, peak, flat, valley power consumption and costs, providing data support for time-sharing power consumption of factories and optimization of cost-effectiveness.

Analysis report

Statistical analysis of energy utilization, line loss, equipment operation, etc. in the factory by year, month, and day, so that users can fully understand the operation of the system, and provide users with a data basis to facilitate users to find equipment abnormalities and find out improvement points , and tap the energy-saving potential according to the energy consumption situation.

Related Products

Power Analyzer

Standard:

2014/35/EU

2014/30/EU

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Quality Analysis
  • High Precious 0.2s
  • 32G SD Card
  • Multi-Communication
  • Modbus-RTU RS485
  • Modbus-TCP Ethernet
  •  Profibus-DP

Three-phase KWH Meter with MID

Standard:

2014/30/EU

2014/32/EU

2014/35/EU

IEC62052-11, IEC62053-22

EN61010-1, EN61000-3

Certificate:

Feature:
  • 3P3L & 3P4L
  • Direct load 80A or via CT
  • Multi-Tariffs
  • Cost-effective

4G Wireless Three-phase Power Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • 4G Wireless
  • Electric Parameter
  • Residual Current
  • Cable Temperature
  • 4DI/2DO

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

    Top