What’s the Function of Acrel ADL400 Series Three-phase KWH Meter with MID?
What’s the Specification of Acrel ADL400 Series Three-phase KWH Meter with MID?
Panel | ![]() |
![]() |
Specification | ADL200 | ADL400 |
Phase | Single-phase | Three-phase |
What’s the Parameter of Acrel ADL400 Series Three-phase KWH Meter with MID?
Project | Performance parameter | ||
Specification | 3 phase 3 wires, 3 phase 4 wires | ||
Measurement |
Voltage |
Reference voltage | 3×100V\3×380Vac、3×57.7/100Vac、 3×220/380Vac (Can normally work under 1.2 times of rated voltage) |
Consumption | <10VA(Single phase) | ||
Impedance | >2MΩ | ||
Accuracy class | Error±0.2% | ||
Current | Input current | 3×1(6)A, 3×10(80)A | |
Consumption | <1VA Single phase rated current | ||
Accuracy class | Error±0.2% | ||
Power | Active, reactive, apparent power, error±0.5℅ | ||
Frequency | 45~65Hz,Error±0.2% | ||
Metering |
Energy | Active energy(Accuracy class: 0.5) reactive energy(Accuracy class 2) | |
Clock | ≤0.5s/d | ||
Digit signal | Energy pulse output | 1 active photocoupler output | |
Pulse |
Width of pulse | 80±20ms | |
Pulse constant | 400imp/kWh,10000imp/kWh(Correspond with the basic current) | ||
Communication
|
Interface and communication protocol | RS485:Modbus RTU | |
Range of Communication address | Modbus RTU:1~ 247; | ||
Baud rate | 1200bps~19200bps |
Show More
How does the Acrel ADL400 Series Three-phase KWH Meter with MID?
How to Install the Acrel ADL400 Series Three-phase KWH Meter with MID?
Current Input via Direct Connect | Current Input via Current Transformer |
![]() |
![]() |
Dimension of ADL400 (Current Input via Direct Connect) | Dimension of ADL400 (Current Input via CTs) |
![]() |
![]() |
PIN/Terminal Overview of ADL400 (Direct Connect Type) | PIN/Terminal Overview of ADL400 (CT Operated Type) |
![]() |
![]() |
Power Wiring: 3-phase 4-wire via direct connect | Power Wiring: 3-phase 4-wire CT operated |
![]() |
![]() |
Power Wiring: 3-phase 3-wire via direct connect | Power Wiring: 3-phase 3-wire CT operated |
![]() |
![]() |
RS485 Wired Communication of ADL400 (Direct Connect Type) with IoT Gateway | RS485 Wired Communication of ADL400 (CT Operated Type) with IoT Gateway |
Show More
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, feeling.chang@email.acrel.cn
Got a Question? Get your Answer
We have our own Factory and R&D Center
Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer
CNAS, ISO14001, ISO27001, ISO9001
CE, IEC, MID, UL, EAC, ROHS, REACH
Competitive Price with High Quality
2 Years
Purchasing according to your needs, no MOQ limit
Sample takes 3 days; Bulk purchase takes 1 month
2014/30/EU
EN IEC 61000
IEC 62052
IEC 62053
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
2014/35/EU
EN 61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
IEC 62052
IEC 62053
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/35/EU
2014/30/EU
2014/30/EU
EN IEC 61000
2014/35/EU
EN 61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
2014/32/EU
2014/35/EU
IEC62052-11, IEC62053-22
EN61010-1, EN61000-3
2014/35/EU
2014/30/EU
Standard Lead Time:
Sample: 2 days
Bulk: 1 month