Core Advantages
Why Acrel’s Telecom Solar Systems?
Multi-Circuit Monitoring & Energy Optimization
Complex Load Management
Granular Energy Analytics
Fault Diagnosis
Synergy with Solar Systems
Industry-Leading Solar Efficiency
Acrel-2000MG Microgrid System
energy management and dispatch system
off-grid/grid-tied microgrids
multi-energy coordination and efficiency optimization
24/7 Remote Operation
AcrelCloud Platform
Monitor Global Sites via IoT
Receive Instant Alerts & Control Systems Anytime, Anywhere
Intelligent Battery Health Management
Acrel-BMS
Real-Time SOC/SOH Monitoring
AI-Powered Optimization
Extend Battery Lifespan by 30%
Success Cases
Technical Highlights & Success Stories
Feature Diesel Generator Acrel Solar System Annual Cost $50,000 $15,000 CO2 Emissions 120 tons/year 0 tons/year Maintenance Monthly Checks Remote Diagnostics
Project: Solarization of 2000+ Telecom Towers in Mountainous Region
Challenge : Unstable grid, 40% downtime.
Solution : Acrel-2000MG + APV Monitoring + ANet IoT Gateway.
Result : 100% uptime, $100K/year OPEX saved.
Integrated Solutions
Acrel Products in Your Telecom Solar Power System
Multi-Circuit Power Metering @ Multi-Circuit Precision Monitoring & Energy Optimization
System DC systemDC systemAC systemAC systemSpecification AMC16L-DETT DJSF1352/RN DTSD1352-4S ADW300 Channels 6 ch 1 ch 4 ch 1 ch Photo Sensor Interface Terminal block Terminal block RJ12 Terminal block Communication Modbus-RTU RS485 Modbus-RTU RS485 Modbus-RTU RS485 Modbus-RTU Modbus-TCP 4G WIFI LORAWAN Customers American Tower Vodafone Orange Wallbox Helios Tower Edgepoint TASC Tower IHS Tower
1.1 Monitor multiple circuits (e.g., RF equipment, cooling systems, backup batteries) in a single device.
1.2 Detect overloads or phase imbalances to prevent downtime.
2.1 Track energy consumption by circuit (e.g., "5G AAU vs. BBU Power Usage").
2.2 Generate reports for OPEX optimization and carbon footprint reduction.
3.1 Compare solar generation vs. load demand per circuit for energy balance.
3.2 Prioritize solar power to high-priority equipment (e.g., core network devices).
Lead-acid Battery Management @ Real-Time SOC/SOH Monitoring
cell Voltage
internal Resistance
negative post Temperature
string Current
Charging & Discharging
ambient Temperature
Collect data from battery cell monitoring module
perform data processing, analysis, alarm generation, storage and upload
Solar Efficiency Management @ Multi-energy coordination and efficiency optimization
Intelligently dispatches PV, energy storage, diesel generators, and grid power for optimal energy allocation.
Supports priority settings (e.g., "PV first, storage backup, diesel as last resort").
Adjusts storage charging/discharging based on real-time load demands (e.g., peak/off-peak usage of 5G equipment).
Sheds non-critical loads (e.g., nighttime HVAC) to prioritize telecom devices.
Forecasts PV generation using weather data and dynamically adjusts storage SOC thresholds.
Peak shaving: Prioritizes storage usage during high electricity price periods.
24/7 Remote Operation @ Monitor Global Sites via IoT, Receive Instant Alerts & Control Systems Anytime, Anywhere
Certificate:
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Feature:
Protection
WIFI 4G Ethernet RS485
C Curve
Real Time Measurement
Standard:
2014/30/EU
EN IEC 61000
IEC 62052
IEC 62053
Certificate:
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Feature:
U, I, P, Q, S, PF, F
3P4L 3P3L 1P3L
response ≤ 100ms
Modbus-RTU RS485
Feature:
U, I, P, Q, S, PF, F
Single phase
with 80A, 120A, 200A, 300A CT
response ≤ 100ms
Modbus-RTU RS485
Certificate:
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Feature:
AC&DC System
12 DC channels Max.
8 Three-phase Max.
24 Single-phase Max.
Dual Source
DI/DO
Temp.&Humidity
Feature:
AC System
Single-phase
Three-phase
10(63)A
4G CE RS485
Real Time Monitoring
Alarm
Feature:
Telecom Tower
Grid, Generator, Tenants, Soalr, Battery
AC & DC System
Single & Three Phase
Multi Circuits
DC 12 24 48 Auxiliary Power Supply
RS485 Modbus-RTU
Ethernet Modbut-TCP