Multi Circuits Dual Source Energy Meter

DTSD1352-4S

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase or 12 Channels of Single-phase
  • Communication RS485 Modbus-RTU
  • Identify Generator or Utility Power

Feedback

What Do Our Customers Say?

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Function of Acrel DTSD1352 Series Multi Circuits Dual Source Energy Meter?

Monitor

  • Electrical Parameters
  • Voltage, Current, Active Power, Reactive Power, Frequency, Power Factor, 2-31st Harmonic etc

  Tariff

  • 1~4 kinds of Tariffs
  • Peak, Standard, Off-peak

  Installation

  • Split-core CT with RJ12 Interface

Switch Input

  • 4 channels Passive Dry Contact Input, built-in Power Supply
  • 2 channels Active Wet node Input, Identify Generator or Utility Power

Specification

What’s the Specification of Acrel DTSD1352-4S series Multi Circuits Dual Source Energy Meter?

In some places where utility power is unstable and unreliable, many buildings have adopted their own private generators as a backup power source to provide a continuous and uninterrupted power source.

Dual source energy meters are digital dual meters that offer comprehensive 3-phase electrical instrumentation and load management facilities in a compact and rugged package for the dual source energy Utility (U) and Generator (G)

It provides two counters showing energy consumption on public electricity board (EB) and diesel generator ( DG).

Parameter

What’s the Parameter of Acrel DTSD1352 Series Multi Circuits Dual Source Energy Meter?

Auxiliary Power AC/DC 85~265V; power consumption≤10VA;
Input Signal Frequency 45~65Hz;
Voltage Rated value: AC 3×220V/380V;
Overload: 1.2 times rated value (continuous); 2 times rated value/1 second;
power consumption: ≤ 0.5VA(each channel);
Current Rated value: Secondary input rated current:50mA
Overload: 1.2 times rated value (continuous); 10 times rated value/1 second;
power consumption: ≤ 0.5VA(each channel);
Measurement Accuracy Frequency: 0.05Hz, voltage and current: 0.5 class, active energy: 1 class, reactive energy: 2 class; 2nd to 31st harmonic accuracy: ±1%;
Function Pulse output Output method: optocoupler pulse with open collector (and active open input can only be either-or.);
communication RS485 interface, Modbus-RTU protocol; baud rate 1200~38400;
Switch Input 2-way or 4-way passive dry contact input, built-in power supply;

2-way active wet node input (AC220V), identify the oil generator and mains access (and pulse output can only be either-or.);

Output Output method: relay normally open contact output;

Contact rating: AC 250V/3A  DC 30V/3A;

Paired Current Transformer

Phase Specification Ratio Cable Accuracy Installation Diameter
Three-phase AKH-0.66/K-Φ10N 50A/20mA 50A/20mA (1+0.2)m 0.50% Open、RJ12 φ10mm
AKH-0.66/K-Φ16N 100A/50mA 100A/50mA (1+0.2)m 0.50% Open、RJ12 φ16mm
AKH-0.66/K-Φ24N 200A/50mA 200A/50mA (1+0.5)m 0.50% Open、RJ12 φ24mm
AKH-0.66/K-Φ24N 250A/50mA 250A/50mA (1+0.5)m 0.50% Open、RJ12 φ24mm
AKH-0.66/K-Φ36N 400A/50mA 400A/50mA (1+0.5)m 0.50% Open、RJ12 φ36mm
AKH-0.66/K-Φ36N 600A/50mA 600A/50mA (1+0.5)m 0.50% Open、RJ12 φ36mm
AKH-0.66 Z-3*Φ15Y(1/0.5) 100A/50mA 100A/50mA (1+0.5)m 0.20% Closed、RJ12 φ15mm
AKH-0.66/W-9NY 50A/20mA 50A/20mA (1+0.2)m 0.20% Closed、RJ12 φ9mm
AKH-0.66/W-12NY 100A/50mA 100A/50mA (1+0.2)m 0.20% Closed、RJ12 φ12mm
AKH-0.66/W-20Y 200A/50mA 200A/50mA (1+0.5)m 0.20% Closed、RJ12 φ20mm
AKH-0.66 W-20Y(1/0.5) 250A/50mA 250A/50mA (1+0.5)m 0.20% Closed、RJ12 φ20mm
AKH-0.66/W-30NY 250A/50mA 250A/50mA (1+0.5)m 0.20% Closed、RJ12 φ31*13mm
AKH-0.66/W-45NY 400A/50mA 400A/50mA (1+0.5)m 0.20% Closed、RJ12 φ45mm
AKH-0.66/W-45NY 600A/50mA 600A/50mA (1+0.5)m 0.20% Closed、RJ12 φ45mm
AKH-0.66-TD-Φ60-NY 300-1000A/50mA (1+0.5)m 0.20% Closed、RJ12 φ60mm
AKH-0.66-TD-Φ70-NY 200-1200A/50mA (1+0.5)m 0.20% Closed、RJ12 φ73mm
AKH-0.66-TD-50III-NY 300-800A/50mA (1+0.5)m 0.20% Closed、RJ12 φ52*30mm
AKH-0.66-TD-80III-NY 600-1600A/50mA (1+0.5)m 0.20% Closed、RJ12 φ82*32mm
Single-phase AKH-0.66 W-12Y(1/0.5) 100A/50mA 100A/50mA (1+0.5)m 0.20% Closed、RJ12 φ12mm

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

Dimension

Terminal

2DI 2DO
6DI 1DO

Wiring

Three phase Four Wire
Three phase Three Wire
Single phase

Why choose Acrel?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

AMC16L-DETT DC Energy Meter with 6 Circuits

Feature:
  • -48V DC Auxi. Power Supply
  • 6 DC channels
  • Power for Hall Sensor

Four Circuit Three-phase Meter 

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

 

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase
  • Communication RS485 Modbus-RTU
  • Optional Function: 12DI/4DO, 12 Temperature, 4 Leakage Current

LCD Three-phase Four Circuit Meter 

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase
  • Communication RS485 Modbus-RTU
  • Optional Function: 12DI/4DO, 12 Temperature, 4 Leakage Current

AMC200L-12DE DC Power Meter with 12 Circuits RJ12

Feature:
  • Working -48V DC
  • Auxi. Power Supply DC-40V~-60V
  • Modbus-RTU RS485, 4G
  • 12 channels of DC
  • Hall Sensor
  • RJ12 interface
  • Active 2DI + Passive 4DI + 2DO
  • 4 NTC Temperature
  • 1 Temperature &Humidity

Single-phase Multi-Circuit Meter

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN IEC 61000

EN61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Modular Design
  • Max 36 Channels of Single-phase
  • High Accuracy 0.5s Class
  • Communication RS485, CE

Dual-circuit AC Power Meter for Data Center

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Measure Electricity
  •  Power Quality
  • Dual Incoming Circuits

DTSD1352-4S Multi Channels Meter for Telecom Tower

Standard:

2014/30/EU

EN 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • -DC48V Auxi. Power
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase or 12 Channels of Single-phase
  • Communication RS485 Modbus-RTU
  • Identify Generator or Utility Power

DC Power Meter RS485

Standard:

2014/30/EU

2014/35/EU

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Dual DC Circuits
  • Secondary RS485
  • DC1000V
  • 0.5s Accuracy
  • Power supply for the Hall sensor

AMC200L-4/8E3 AC Power Meter with 4 or 8 Circuits RJ12

Feature:
  • full power parameter measurement
  • Modbus-RTU RS485
  • 4 or 8 channels of Three-phase
  • 12 or 24 channels of Single-phase
  • Current Sensor RJ12
  • 6DI + 2DO
  • 4 NTC Temperature
  • 1 Temperature &Humidity

Three-phase Multi Circuit Meter

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN IEC 61000

EN61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Modular Design
  • Max 12 Channels of Three-phase
  • High Accuracy 0.5s Class
  • Communication RS485, CE
    Top