What Do Our Customers Say?
“ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "
Arnold
Philippines
Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.
Tuan
Vietnam
What’s the Function of Four Circuit Three-phase Meter?
What’s the Specification of Acrel ADW200 series Four Circuit Three-phase Meter?
Photo | |||
Specification | ADW200 | ADW210 | ADW220 |
Optional Modular | |||
Optional Function | MK
12DI / 4DO |
MTL
12 channels Temperature |
AWT100
Wireless Communication 4G WIFI LORA LORAWAN |
What’s the Parameter of Four Circuit Three-phase Meter?
Parameters | Description | |
Input |
Voltage |
AC 3×220V/380V |
Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s |
||
Power consumption:≤ 0.5VA | ||
Current |
AC 5A、100A、400A、600A;(external open-type CT) | |
Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s |
||
Power consumption:≤ 0.5VA | ||
Frequency | 45~65Hz | |
Measuring
Accuracy |
Voltage&Current | Class 0.5 |
Active Power | Class 1 | |
Reactive Power | Class 2 | |
Frequency | 0.05Hz | |
2~31st harmonic | ± 1% | |
Auxiliary Power | AC/DC 85~265V; Consumption≤10VA; | |
EMC | Better than grade 3 | |
Safety | Withstand Voltage | >AC 2000V/1min |
Insulation Resistance | >100MΩ | |
Environment | Working Temperature | -20℃~+60℃ |
Storage Temperature | -40℃~+70℃ | |
Humidity | ≤95% (No condensation) | |
Altitude | ≤2500m |
Paired Current Transformer
Paired CT | Primary Current | Secondary Current | Aperture(Hole size) | Accuracy Class |
AKH-0.66/K-φ10N | 5A | 1.25mA | 10mm | Class 0.5 |
AKH-0.66/K-φ16N | 100A | 20mA | 16mm | Class 0.5 |
AKH-0.66/K-φ24N | 400A | 100mA | 24mm | Class 0.5 |
AKH-0.66/K-φ36N | 600A | 100mA | 36mm | Class 0.5 |
AKH-0.66-L-45
(for residual current) |
/ | / | / | Class 1 |
How to Install the Four Circuit Three-phase Meter?
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]
Got a Question? Get your Answer
We have our own Factory and R&D Center
Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer
CNAS, ISO14001, ISO27001, ISO9001
CE, IEC, MID, UL, EAC, ROHS, REACH
Competitive Price with High Quality
2 Years
Purchasing according to your needs, no MOQ limit
Sample takes 3 days; Bulk purchase takes 1 month
IEC 62052
IEC 62053
2014/30/EU
EN IEC 61000
2014/35/EU
EN IEC 61000
EN61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
2014/35/EU
EN 61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
2014/35/EU
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
EN 61326-1-2013
EN IEC 61000-3-2:2019+A1:2021
EN 61000-3-3:2013+A2:2021
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN 61000
2014/35/EU
EN 61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]