What Do Our Customers Say?
“ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "
Arnold
Philippines
Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.
Tuan
Vietnam
What’s the Function of Acrel AMC16Z-ZA series Dual-circuit AC Power Meter for Data Center?
What’s the Specification of Acrel AMC16Z-ZA series Dual-circuit AC Power Meter for Data Center?
Dual AC Incoming Circuits Monitoring
● A+B Dual independent AC Circuits Monitoring ● Full Electrical Parameters Monitoring ● Power Quality Analyzing |
|
Power Quality Analysis
● 2nd~63rd and total Harmonic ● Current&Voltage Unbalance Degree ● Current K Coefficient (KF) ● Telephone Waveform Factor (THFF) ● Voltage Crest Coefficient (CF) |
|
Multiple Extra Function
● 6-channel DI (digital input) ● 2-channel DO (digital output) ● Temperature&Humidity Monitoring ● Leakage Current Monitoring |
What’s the Parameter of Acrel AMC16Z-ZA series Dual-circuit AC Power Meter for Data Center?
Function | Description |
Measurement
(Common) |
Three-phase AC kWh, kVarh, Active Power, Reactive Power, Current, Voltage, Power Factor, Apparent Power, Frequency, Zero ground voltage, neutral line current |
Measurement
(Power Quality) |
total harmonic content (THD), 2-63 harmonics, current, and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF), telephone waveform factor (THFF), peak voltage, voltage, and current sequence quantity |
Temp.&Humidity
Monitoring |
Temperature Monitoring Range: -40℃~+99℃
Humidity Monitoring Range: 20%~90% |
Leakage Current | 2-channel Leakage Current Measurement |
Accuracy | Electrical Parameter Metering Accuracy: Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric energy level 1
Temperature Metering Accuracy: ±1℃; Temperature Metering Accuracy: ±5% |
Communication | RS485 Interface (MODBUS-RTU protocol) |
DO
(Switch Output) |
2-channel DO (Digital Output); 3A 250VAC/3A 30VDC |
DI
(Switch Input) |
6-channel DI (Digital Input); dry contact |
Parameter | Description&Value | |
Voltage
Input |
Rated Voltage | 3×220~264Vac L-N |
Reference Frequency | 45~65Hz | |
Current
Input |
Rated Current | 3×1(6)A AC (via CTs) |
Power
Supply |
Source from | Voltage Input (Voltage signal input for both measurement and power supply) |
Installation | DIN-rail | 35mm standard DIN-rail Installation |
Phase
Wiring |
3P4W | 3-phase 4-wire |
Safety | Insulation | All terminals and the insulation resistance between the conductive pieces not less than 100MΩ |
Withstand voltage | A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs, the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover |
Condition | Description&Value |
Temperature | Operating Temperature: -20℃~+55℃; Storage Temperature: -40°C ~+70°C |
Humidity | ≤95%RH, no condensation, without corrosive gas |
Altitude | ≤ 2000m |
How does Acrel AMC16Z-ZA series Dual-circuit AC Power Meter for Data Center work?
How to Connect the Acrel AMC16Z-ZA series Dual-circuit AC Power Meter for Data Center?
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]
Got a Question? Get your Answer
We have our own Factory and R&D Center
Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer
CNAS, ISO14001, ISO27001, ISO9001
CE, IEC, MID, UL, EAC, ROHS, REACH
Competitive Price with High Quality
2 Years
Purchasing according to your needs, no MOQ limit
Sample takes 3 days; Bulk purchase takes 1 month
ANSI/TIA-942
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]