What Do Our Customers Say?
Acrel is one of the best supplier for me. They are so easy to communicate and very friendly. They even give an online tour of their factory. Looking forward for more business together in the future.
Liezel
Philippines
My first contact with ACREL was through Mrs. Feeling Chang. He was extremely friendly, approachable and very helpful. It will be the beginning of a long partnership between Bikoelectronics and Acrel.
Vanessa
Portugal
“ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "
Arnold
Philippines
Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.
Tuan
Vietnam
What’s the Highlight of Acrel DTSD1352-4S Series AC 4 Three-phase or 12 Single-phase Multi Circuit Meter for Cell Tower?
Real-Time Monitoring
Voltage- Va, Vb, Vc
Current- la, Ib, lc
Active power - Pa, Pb, Pc, ∑P
Reactive power - Qa, Qb, Qc, ∑Q
Apparent power - Sa, Sb, Sc, ∑S
Power Factor- PFa, PFb, PFc, ∑PF
Active energy - each phase kWh, total kWh
Reactive energy - each phase kvarh, total kvarh
How does DTSD1352-4S Series AC 4 Three-phase or 12 Single-phase Multi Circuit Meter for Cell Tower Network?
What’s the Specification of Acrel DTSD1352-4S series AC 4 Three-phase or 12 Single-phase Multi Circuit Meter for Cell Tower?
In some places where utility power is unstable and unreliable, many buildings have adopted their own private generators as backup power sources to provide a continuous and uninterrupted power source.
Dual source energy meters are digital dual meters that offer comprehensive 3-phase electrical instrumentation and load management facilities in a compact and rugged package for the dual source energy Utility (U) and Generator (G)
It provides two counters showing energy consumption on public electricity board (EB) and diesel generator ( DG).
What’s the Parameter of Acrel DTSD1352-4S Series AC 4 Three-phase or 12 Single-phase Multi Circuit Meter for Cell Tower?
Auxiliary Power | AC/DC 85~265V; power consumption≤10VA; | ||
Input Signal | Frequency | 45~65Hz; | |
Voltage | Rated value: AC 3×220V/380V; | ||
Overload: 1.2 times rated value (continuous); 2 times rated value/1 second; | |||
power consumption: ≤ 0.5VA(each channel); | |||
Current | Rated value: Secondary input rated current:50mA | ||
Overload: 1.2 times rated value (continuous); 10 times rated value/1 second; | |||
power consumption: ≤ 0.5VA(each channel); | |||
Measurement Accuracy | Frequency: 0.05Hz, voltage and current: 0.5 class, active energy: 1 class, reactive energy: 2 class; 2nd to 31st harmonic accuracy: ±1%; | ||
Function | Pulse output | Output method: optocoupler pulse with open collector (and active open input can only be either-or.); | |
communication | RS485 interface, Modbus-RTU protocol; baud rate 1200~38400; | ||
Switch | Input | 2-way or 4-way passive dry contact input, built-in power supply;
2-way active wet node input (AC220V), identify the oil generator and mains access (and pulse output can only be either-or.); |
|
Output | Output method: relay normally open contact output;
Contact rating: AC 250V/3A DC 30V/3A; |
Paired Current Transformer
Phase | Specification | Ratio | Cable | Accuracy | Installation | Diameter |
Three-phase | AKH-0.66/K-Φ10N 50A/20mA | 50A/20mA | (1+0.2)m | 0.50% | Open、RJ12 | φ10mm |
AKH-0.66/K-Φ16N 100A/50mA | 100A/50mA | (1+0.2)m | 0.50% | Open、RJ12 | φ16mm | |
AKH-0.66/K-Φ24N 200A/50mA | 200A/50mA | (1+0.5)m | 0.50% | Open、RJ12 | φ24mm | |
AKH-0.66/K-Φ24N 250A/50mA | 250A/50mA | (1+0.5)m | 0.50% | Open、RJ12 | φ24mm | |
AKH-0.66/K-Φ36N 400A/50mA | 400A/50mA | (1+0.5)m | 0.50% | Open、RJ12 | φ36mm | |
AKH-0.66/K-Φ36N 600A/50mA | 600A/50mA | (1+0.5)m | 0.50% | Open、RJ12 | φ36mm | |
AKH-0.66 Z-3*Φ15Y(1/0.5) 100A/50mA | 100A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ15mm | |
AKH-0.66/W-9NY 50A/20mA | 50A/20mA | (1+0.2)m | 0.20% | Closed、RJ12 | φ9mm | |
AKH-0.66/W-12NY 100A/50mA | 100A/50mA | (1+0.2)m | 0.20% | Closed、RJ12 | φ12mm | |
AKH-0.66/W-20Y 200A/50mA | 200A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ20mm | |
AKH-0.66 W-20Y(1/0.5) 250A/50mA | 250A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ20mm | |
AKH-0.66/W-30NY 250A/50mA | 250A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ31*13mm | |
AKH-0.66/W-45NY 400A/50mA | 400A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ45mm | |
AKH-0.66/W-45NY 600A/50mA | 600A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ45mm | |
AKH-0.66-TD-Φ60-NY | 300-1000A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ60mm | |
AKH-0.66-TD-Φ70-NY | 200-1200A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ73mm | |
AKH-0.66-TD-50III-NY | 300-800A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ52*30mm | |
AKH-0.66-TD-80III-NY | 600-1600A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ82*32mm | |
Single-phase | AKH-0.66 W-12Y(1/0.5) 100A/50mA | 100A/50mA | (1+0.5)m | 0.20% | Closed、RJ12 | φ12mm |
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]
Got a Question? Get your Answer
We have our own Factory and R&D Center
Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer
CNAS, ISO14001, ISO27001, ISO9001
CE, IEC, MID, UL, EAC, ROHS, REACH
Competitive Price with High Quality
2 Years
Purchasing according to your needs, no MOQ limit
Sample takes 3 days; Bulk purchase takes 1 month
IEC 62052
IEC 62053
2014/30/EU
EN IEC 61000
2014/35/EU
EN IEC 61000
EN61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
EN 61326-1-2013
EN IEC 61000-3-2:2019+A1:2021
EN 61000-3-3:2013+A2:2021
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
2014/35/EU
EN 61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
EN 61326-1-2013
EN IEC 61000-3-2:2019+A1:2021
EN 61000-3-3:2013+A2:2021
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
2014/35/EU
EN IEC 61000
EN61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
2014/35/EU
EN IEC 61000
EN61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
2014/35/EU
EN 61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
2014/30/EU
EN IEC 61000
2014/35/EU
EN 61010
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]