What’s the Highlight of Acrel DCIM Data Center Power Distribution Monitoring Solution?
What’s the Components of Acrel DCIM Data Center Power Distribution Switchgear?
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]
How does Acrel AMC100 Series DC & AC Multi Channels Electricity Meter work?
AC
A+B independent 2-channel:
Full electrical parameter measurement, 63rd harmonic, Neutral current, neutral voltage
8DI4DO+1 temperature and humidity
Ethernet (optional)
3 channels RS485 (2 channels uplink touch screen and dynamic system, 1 channel downlink sub-module)
Comes with DC24V voltage output, power supply for 3 split modules + 1 touch screen
DC
A+B independent 2-channel:
Full electrical parameter measurement
8DI4DO+1 temperature and humidity
Ethernet (optional)
3 channels RS485 (2 channels uplink touch screen and dynamic system, 1 channel downlink sub-module)
Comes with DC24V voltage output, power supply for 3 split modules + 1 touch screen
A+B independent 2-channel:
24 or 15 all-electric parameters on each side
48/30 active switch input
1 channel RS485 communication
A+B independent 2-channel:
24 or 15 all-electric parameters on each side
1 channel RS485 communication
9A - 50A/50mA, φ9mm, 0.2 class, 10Ω
9B - 50A/50mA, φ9mm, 0.2 class, 10Ω
15A - 100A/50mA, φ15mm, 0.2 class, 10Ω
15B - 100A/50mA, φ15mm, 0.2 class, 10Ω
50A/10mA
50A/50mA
Din-rail
9N - 50A/50mA, φ9mm, 0.2 class, 10Ω
12N - 100A/50mA, φ12mm, 0.2 class, 10Ω
20N - 200A/50mA, φ20mm, 0.2 class, 10Ω
30N - 400A/50mA, 31*13mm, 0.2 class, 10Ω
Incoming Line
0-1000A/5V
43*13mm
Outgoing Line
100A/5V
20.5*10.5mm
How does Acrel AMC16Z Series DC & AC Multi Channels Electricity Meter work?
AC
A+B independent 2-channel:
Bus voltage, current, active power, reactive power, power factor,
active energy, reactive energy, 2-63rd harmonics of the three-phase main incoming line,
Neutral line current, neutral ground voltage,
6DI2DO, 2 leakage current, 1 temperature and humidity,
1 RS485 communication,
With DC24V voltage output, power supply for shunt module and touch screen
DC
A+B independent 2-channel:
Bus voltage, current, power, active energy of the main incoming line,
6DI2DO, 1 channel temperature and humidity,
1 channel RS485 communication,
Comes with DC24V voltage output to supply power to the shunt module and touch screen,
With 2 channels of ±12V voltage output, power supply for the main channel Hall sensor
A+B independent 2-channel:
Outgoing line voltage, 12/24 channels of current,
power and energy on each side,
24/48 active switch inputs,
1 channel RS485 communication
A+B independent 2-channel:
24-channel outgoing switch value collection on each side,
1 channel RS485 communication
Monitor the busbar voltage, busbar-to-ground voltage, busbar insulation status, etc.
of the A+B dual DC incoming circuit.
One RS485 interface is used to connect to the touch screen or RS485 hub,
and it is also equipped with 6 RS485 interfaces for external digital intelligence.
Leakage current sensor, can measure up to 192 branches
It is selected when externally equipped with an analog leakage current sensor.
It is connected to the main module through the RS485 interface for monitoring the insulation state of the shunt.
It can be expanded to 8 sets at most.
It can be configured as the insulation state of 24 shunts of single-channel DC outlet,
and 1-channel RS485 communication.
Outgoing circuit built-in Current Sensor, din-rail installation
1-channel incoming line + 21-channel outgoing line full power + 21-channel active switch
4-channel passive DI+2DO
1 channel temperature + 1 channel zero sequence current + 1 channel leakage current
1-way zero-ground voltage detection
AC and DC integrated module
2 AC incoming lines + 1 DC incoming line
6 passive DI+2DO
1 channel temperature + 2 channel leakage current
Neutral ground voltage
With DC24V voltage output, power supply for shunt module and touch screen
50a/50mA
100A/50mA
(5-200)A/20mA
(100-200)A/20mA
(200-400)A/50mA
50A/50mA
50A/25mA
Incoming Line
200-800A
Outgoing Line
50-500A
Outgoing Line
10mA / 5V
What’s the System of Acrel DCIM Data Center Power Distribution Monitoring?
Got a Question? Get your Answer
We have our own Factory and R&D Center
Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer
CNAS, ISO14001, ISO27001, ISO9001
CE, IEC, MID, UL, EAC, ROHS, REACH
Competitive Price with High Quality
2 Years
Purchasing according to your needs, no MOQ limit
Sample takes 3 days; Bulk purchase takes 1 month
ANSI/TIA-942
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Standard Lead Time:
Sample: 2 days
Bulk: 1 month
Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]